CT-4000 Battery Testing System
CE-4008Q-5V20A
Highly accurate 4-range tester, master of detail realism. Current ranges of 5mA~1A , 30mA~6A, 60mA~12A, 150mA~20A can be selected to realize the controllable accuracy of small current in small range.
| Flawless in milliseconds, precision beyond limits. | |
| Laptop and Tablet Battery | Balance between safety and energy density: while increasing the energy density of the battery to increase range, ensure the safety of the battery system and prevent safety risks caused by overheating and overcharging. |
| Electric Transportation Battery | Electric Hoverboard, electric scooters, e bikes, and electric motorcycles are changing the way people travel, with the development of battery technology being at the core of this transformation. The main issues faced by electric bicycle batteries include battery cost, range, the popularity of charging infrastructure, thermal management of batteries, and safety. As battery technology continues to advance, it provides more reliable power support for these intelligent devices. |
| Electric Bicycles | Electric Hoverboard, electric scooters, e bikes, and electric motorcycles are changing the way people travel, with the development of battery technology being at the core of this transformation. The main issues faced by electric bicycle batteries include battery cost, range, the popularity of charging infrastructure, thermal management of batteries, and safety. As battery technology continues to advance, it provides more reliable power support for these intelligent devices. |
| Steady-state data acquisition. Embracing the energy of precision. | |
| Current Accuracy | ±0.05% F.S. |
| Recording Frequency | 10Hz |
| Sampling Time | 100ms |
| Current Response Time | ≤1ms |
| Energy Efficiency | >65% |
| Off-Line Test | 1GB |
| Stable performance parameters to ensure accurate and reliable test data. At the same time, the product adopts modular design with each unit having 8 channels, which can be independently data acquisition and programmed with the maximum number of editable lines supporting 254 lines. | |
| Voltage & Current | 5V6mA |
| Range / Current | Range1: 5mA ~ 1A |
| Range2: 30mA ~ 6A | |
| Range3: 60mA ~ 12A | |
| Range4: 150mA ~ 20A | |
| *Other models can be customized according to voltage and current requirements. | |
| Voltage | |
| CV output range | 0.025V ~ 5V |
| Min discharge voltage | 2V (2m wire length) |
| Accuracy | ±0.02% of F.S. |
| Stability | 0.1% of F.S. |
| Current | |
| Output range/channel | Range1: 1A |
| Range2: 6A | |
| Range3: 12A | |
| Range4: 20mA | |
| Accuracy | ±0.05% of F.S. |
| Stability | 0.1% of F.S. |
| Constant voltage cut-off current | Range1: 2A |
| Range2: 12A | |
| Range3: 24A | |
| Range4: 40mA | |