CT-4000 Battery Testing System
CT-4008Q-5V100mA-124
For Coin Cells, Super Capacitors, Three-Electrode Systems Testing and etc. The product(CT-4008Q-5V100mA-124) adopts modular design with each unit having 8 channels, which can be independently data acquisition and programmed with the maximum number of editable lines supporting 254 lines.
| Flawless in milliseconds, precision beyond limits. | |
| Customer Electronic | NEWARE offers a range of testing solutions for Cylindrical and Pouch batteries used in 3C digital products such as smartphones, tablets, and laptops. The equipment is designed with modular components and boasts high-performance features such as rapid response times, exceptional precision, and high sampling rates. Optional SMBus communication functionality is also available, making it a suitable choice for Battery Manufacturers, 3C Manufacturers, Research Institutions, and other organizations with complex testing needs. |
| Coin Cells | NEWARE has created a complete set of solutions for laboratory materials research, including Cycle Life Testing, Rate Charging / Discharging Testing, GITT Testing, DCIR Testing, GSM Testing, dQ/dV Differential Capacity Curve Analysis and other functions. This solution caters to the varying levels of accuracy required for battery testing by Material Manufacturers, Universities, and Research Institutes. |
| Monitor&Alarm System | 1Smoke alarms, monitors, electronic access control systems, and other devices require batteries with high stability. NEWARE's battery testing solutions can perform comprehensive testing on Coin, Cylindrical, and Pouch batteries, including Cycle Life Testing and Pulse Simulation, to ensure their reliability. |
| Unit modularity, powerful performance. | |
| Current Accuracy | ±0.01% F.S. |
| Recording Frequency | 10Hz |
| Sampling Time | 100ms |
| Current Response Time | (10% F.S. ~ 90% F.S.) |
| Minimum Pulse Width | 500ms |
| Off-Line Test | 1GB |
| Stable performance parameters to ensure accurate and reliable test data. At the same time, the product adopts modular design with each unit having 8 channels, which can be independently data acquisition and programmed with the maximum number of editable lines supporting 254 lines. | |
| Voltage & Current | 5V100mA |
| Range / Current | Range1: 0.2μA ~ 0.1mA |
| Range2: 0.1mA ~ 1mA | |
| Range3: 1mA ~ 10mA | |
| Range4: 10mA ~ 100mA | |
| *Other models can be customized according to voltage and current requirements. | |
| Voltage | |
| CV output range | 10mV ~ 5V |
| Min discharge voltage | -5V |
| Accuracy | ± 0.01% of F.S. |
| Stability | ± 0.02% of F.S. |
| Current | |
| Output range/channel | Range1: 0. 2 μA-0.1mA |
| Range2: 0.1mA-1mA | |
| Range3: 1mA-10mA | |
| Range4: 10mA-100mA | |
| Accuracy | ± 0.01% of F.S. |
| CV cut-off current | Range1: 0.1μA |
| Range2: 1μA | |
| Range3: 10μA | |
| Range4: 0.1mA | |
| Stability | ± 0.02% of F.S. |
| Power | |
| Output power/channel | 0.5W |
| Stability | ± 0.1% of F.S. |
| Time | |
| Current response time | ≤1 ms |
| Working step time | ≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms) |