CE-6000-Pro 전력 셀 테스트 시스템
CE-6000-Pro Cell Testing System
Power Cell Testing System의 성능이 전면적으로 업그레이드되어 테스트 표준의 새로운 기준을 제시했습니다. 전원 배터리 R&D 및 제조를 위한 완전히 새로운 테스트 경험을 제공합니다.
Upgraded power cell testing with enhanced voltage and current accuracy.
| Electric Vehicles Parameter Assessment | Power battery technology faces multiple challenges, including enhancing energy density, enabling fast charging, ensuring safety, and improving cost-effectiveness. Laboratory research focuses on addressing these issues in EV power batteries. Researchers explore advanced materials, intelligent management, and green recycling technologies to improve battery performance and ensure safety. These efforts promote environmental sustainability and aid the global energy transition. |
| Electric Transportation Battery | Electric Hoverboard, electric scooters, e bikes, and electric motorcycles are changing the way people travel, with the development of battery technology being at the core of this transformation. The main issues faced by electric bicycle batteries include battery cost, range, the popularity of charging infrastructure, thermal management of batteries, and safety. As battery technology continues to advance, it provides more reliable power support for these intelligent devices. |
| Electric Vehicles | NEWARE provides turnkey solutions for Cell,Module,and Pack batteries testing, offering a range of functions such as Cycle Life Testing, HPPC Testing, and Simulation Testing. The equipment is equipped with an energy feedback feature, which can feed back the residual battery discharge energy to the internal grid, meeting the testing needs of Battery Manufacturers, Electric Vehicle Manufacturers, and Energy Storage Companies. |
| Electric Energy Storage | NEWARE is dedicated to delivering complete energy storage battery solutions that encompass a wide range of applications, including backup power supplies, communication base stations, and photovoltaic / wind power stations. Equipped with advanced software functionality, our solutions can tackle complex testing requirements with ease. |
Performance fully upgraded, testing more reliable.
Supports communication expansion.
The CE-6000-Pro Series Cell Testing System features a comprehensive performance upgrade. Voltage and current measurement accuracy has improved from ±0.05% of F.S. to ±0.02% of F.S., supported by 24-bit high-resolution sampling for greater data precision. Key metrics including current response time, transition time, and minimum pulse width have also been significantly enhanced to accurately capture battery transient characteristics.
- Voltage & Current Accuracy:±0.05% F.S.
- Recording Frequency:100Hz → 200Hz
- Current Response Time:≤3ms → ≤1ms
- Current Conversion Time:≤6ms → ≤2ms
- Minimum Pulse Width:100ms → 10ms
| Voltage | Current | |||||||
| 5V | 75A | 150A | 300A | 600A | 1200A | 1500A | 2400A | 3600A |
| 6V | 75A | 150A | 300A | 600A | 1200A | 1500A | 2400A | 3600A |

Performance fully upgraded, testing more reliable.

Perpetual dedication to safety protection.
- Grid Over/Under-Voltage Protection
- AC Short-Circuit and Phase Loss Protection
- Over-Voltage/Over-Current Output Protection
- Overheating Protection
- Open/Short Circuit Protection
- Emergency Stop Protection
- Self-Diagnosis Protection
- Redundant Voltage Channels Protection
- DC Polarity Reverse Protection
- Power-Off Resumption Protection
- Grid Voltage Phase and Frequency Adaptive
- Adjustable Protection Values for Voltage and Current
- Traceable Protection Log

| 모델 | CE-6006-Pro-6V1200A |
| Voltage | |
| 복도의 범위 | Charging: 0V ~ 6V;Discharge: 1.5V ~ 6V |
| 최소 방전 전압 | 1.5V |
| 정확성 | ±0.02% of F.S. |
| 해상도 비율 | 24bit |
| Current | |
| 복도의 범위 | Range 1: 0.15A ~ 75A |
| Range 2: 75A ~ 150A | |
| Range 3: 150A ~ 300A | |
| Range 4: 300A ~ 1200A | |
| 정확도(독립 범위) | ± 0.02% of F.S. |
| 정전압 차단 전류 | 0.05% F.S. (per independent range) |
| 해상도 비율 | 24bit |
| Power | |
| 단일 채널 출력 전력 | 7.2kW |
| 기계의 출력 전력 | 43.2kW |
| Time | |
| 현재 응답 시간(10% F.S. 90%F.S.까지) | ≤1ms |
| Current conversion time(-90% F.S. TO 90% F.S.) | ≤2ms |
| Minimum work step time | 10ms |